Principle of measurement: The Oximeter principle is as follows: An experience formula of data process is established using Lambert-Beer Law according to Spectrum Absorption Characteristics of Reductive Hemoglobin (Hb) and Oxyhemoglobin (HbO2) in glow & near-infrared zones. The instrument’s operation principle is: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse. Scanning & Recording Technology so that two beams of different wavelengths of lights can be focused onto a human nail tip through a perspective clamp finger-type sensor. Then measured signal can be obtained by a photosensitive element, information acquired through which will be shown on screen through treatment in electronic circuits and microprocessors.
Caution:
- The finger should be placed properly; else, the provided results could be inaccurate
- The photoelectric receiving tube and the SpO2 sensor must be arranged in accordance with the subject’s arteriole position
- The SpO2 sensor shouldn’t be applied at a location or limb linked with the arterial canal or blood pressure cuff or receiving an intravenous injection
- Keep the optical path free from any optical like rubberized fabric
- Refrain excessive ambient lighting such as an infrared heater, direct sunlight, fluorescent lamp, dual ruby light, etc. for protecting it from affecting the measuring results
- Strenuous action of the subject or extreme electrosurgical interference can affect the accuracy
- Testee cannot use enamel or other makeup
- Batteries must be inserted in the proper direction and then replaced by the cover
- The clip must be open as visualized below. The finger must be placed in a proper position
- The patient’s finger must be placed aligned with the clip’s rubber cushions in the right position and then clip the finger
- The switch on the front panel should be pressed
- During the process, the patient should be kept stationary and avoid the finger from shaking
- Information is presented directly on the screen display
- Dimension: 60 mm x 35 mm x 32 mm
- Weight: 50 g
- SPO2 Range: 0% 99%
- SPO2 Resolution: + 1%
- Pulse Rate Range: 30 250 bpm
- Pulse Rate Resolution: + 1 bpm
- Power Requirements: 2 x 1.5 V AAA alkaline battery or rechargeable battery instead, adaptable range: 2.6V 3.6V
- Measurement Performance: The oxyhemoglobin/Pulse value is accurate when the pulse filling rate is 0.4%
- The deviation is smaller than + 1 % when measured in natural indoor lighting conditions
- One size fits all
Package Contents:
- 1 * Pulse Oximeter
- 1 * One hanging rope
- 1 * User Manual
- 1 * Storage bag